Vulnerabilities
Vulnerable Software

Vulnerability Details CVE-2024-1228

Use of hard-coded password to the patients' database allows an attacker to retrieve sensitive data stored in the database. The password is the same among all Eurosoft Przychodnia installations. This issue affects Eurosoft Przychodnia software before version 20240417.001 (from that version vulnerability is fixed).
Exploit prediction scoring system (EPSS) score
EPSS Score 0.001
EPSS Ranking 32.3%
CVSS Severity
CVSS v3 Score 9.8
Products affected by CVE-2024-1228


Contact Us