Vulnerability Details CVE-2022-25755
A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The webserver of an affected device is missing specific security headers. This could allow an remote attacker to extract confidential session information under certain circumstances.
Exploit prediction scoring system (EPSS) score
EPSS Score 0.006
EPSS Ranking 67.7%
CVSS Severity
CVSS v3 Score 7.5
CVSS v2 Score 5.0
Products affected by CVE-2022-25755
-
cpe:2.3:h:siemens:scalance_x302-7eec:-
-
cpe:2.3:h:siemens:scalance_x304-2fe:-
-
cpe:2.3:h:siemens:scalance_x306-1ldfe:-
-
cpe:2.3:h:siemens:scalance_x307-2eec:-
-
cpe:2.3:h:siemens:scalance_x307-3:-
-
cpe:2.3:h:siemens:scalance_x307-3ld:-
-
cpe:2.3:h:siemens:scalance_x308-2:-
-
cpe:2.3:h:siemens:scalance_x308-2ld:-
-
cpe:2.3:h:siemens:scalance_x308-2lh+:-
-
cpe:2.3:h:siemens:scalance_x308-2lh:-
-
cpe:2.3:h:siemens:scalance_x308-2m:-
-
cpe:2.3:h:siemens:scalance_x308-2m_poe:-
-
cpe:2.3:h:siemens:scalance_x308-2m_ts:-
-
cpe:2.3:h:siemens:scalance_x310:-
-
cpe:2.3:h:siemens:scalance_x310fe:-
-
cpe:2.3:h:siemens:scalance_x320-1-2ldfe:-
-
cpe:2.3:h:siemens:scalance_x320-1fe:-
-
cpe:2.3:h:siemens:scalance_x408-2:-
-
cpe:2.3:h:siemens:scalance_xr324-12m:-
-
cpe:2.3:h:siemens:scalance_xr324-12m_ts:-
-
cpe:2.3:h:siemens:scalance_xr324-4m_eec:-
-
cpe:2.3:h:siemens:scalance_xr324-4m_poe:-
-
cpe:2.3:h:siemens:scalance_xr324-4m_poe_ts:-
-
cpe:2.3:h:siemens:siplus_net_scalance_x308-2:-
-
cpe:2.3:o:siemens:scalance_x302-7eec_firmware:-
-
cpe:2.3:o:siemens:scalance_x304-2fe_firmware:-
-
cpe:2.3:o:siemens:scalance_x306-1ldfe_firmware:-
-
cpe:2.3:o:siemens:scalance_x307-2eec_firmware:-
-
cpe:2.3:o:siemens:scalance_x307-3_firmware:-
-
cpe:2.3:o:siemens:scalance_x307-3ld_firmware:-
-
cpe:2.3:o:siemens:scalance_x308-2_firmware:-
-
cpe:2.3:o:siemens:scalance_x308-2ld_firmware:-
-
cpe:2.3:o:siemens:scalance_x308-2lh+_firmware:-
-
cpe:2.3:o:siemens:scalance_x308-2lh_firmware:-
-
cpe:2.3:o:siemens:scalance_x308-2m_firmware:-
-
cpe:2.3:o:siemens:scalance_x308-2m_poe_firmware:-
-
cpe:2.3:o:siemens:scalance_x308-2m_ts_firmware:-
-
cpe:2.3:o:siemens:scalance_x310_firmware:-
-
cpe:2.3:o:siemens:scalance_x310fe_firmware:-
-
cpe:2.3:o:siemens:scalance_x320-1-2ldfe_firmware:*
-
cpe:2.3:o:siemens:scalance_x320-1fe_firmware:-
-
cpe:2.3:o:siemens:scalance_x408-2_firmware:-
-
cpe:2.3:o:siemens:scalance_x408-2_firmware:4.1.3
-
cpe:2.3:o:siemens:scalance_xr324-12m_firmware:-
-
cpe:2.3:o:siemens:scalance_xr324-12m_firmware:4.1.0
-
cpe:2.3:o:siemens:scalance_xr324-12m_ts_firmware:-
-
cpe:2.3:o:siemens:scalance_xr324-12m_ts_firmware:4.1.0
-
cpe:2.3:o:siemens:scalance_xr324-4m_eec_firmware:-
-
cpe:2.3:o:siemens:scalance_xr324-4m_eec_firmware:4.1.0
-
cpe:2.3:o:siemens:scalance_xr324-4m_poe_firmware:-
-
cpe:2.3:o:siemens:scalance_xr324-4m_poe_firmware:4.1.0
-
cpe:2.3:o:siemens:scalance_xr324-4m_poe_ts_firmware:-
-
cpe:2.3:o:siemens:scalance_xr324-4m_poe_ts_firmware:4.1.0
-
cpe:2.3:o:siemens:siplus_net_scalance_x308-2_firmware:*